HSR186 Integrated Relay is applicable to line, transformer, capacitor and buscoupler protection, measuring and controlwhich is mainly for protection of 35KV and below. The device provides communication interfaces and can be installed in switchgear dispersedly, it can also be installed in cabinet in group. The device can compose the automation system with other protections and automation equipment through self-equipped communication interfaces.
Function | Contents | HSR186-I Type | HSR186-II Type | HSR186-III Type |
Protection Function Control Function | Three-stage Voltage Controlled DirectionalOvercurrent (50/51/67P1, 50/51/67P2, 50/51/67P3) | √ | √ | √ |
Inverse Definite Minimum Time Overcurrent Protection (Common, Extraordinary, Extreme) (50/51P_IDMT) | √ | √ | √ | |
Three-stage Voltage Controlled Zero Sequence Directional Protection (50/51/67G1, 50/51/67G2, 50/51/67G3) | √ | √ | √ | |
Inverse time zero-sequence protection (Common, Extraordinary, Extreme) (50/51G_IDMT) | √ | √ | √ | |
Overload Protection (51O) | √ | √ | √ | |
Negative sequence overcurrent Protection (50/51Q) | √ | √ | √ | |
Overvoltage Protection (59P) | √ | √ | √ | |
Undervoltage Protection (27P) | √ | √ | √ | |
Zero Sequence Overvoltage Protection (59G) | √ | √ | √ | |
Under-frequency Load Shedding (81U) | √ | √ | √ | |
Over-frequency Load Shedding (81O) | √ | √ | √ | |
Auto-recloser (79) | √ | √ | √ | |
Manual Synchronous Closing (25M) | √ | √ | √ | |
Directional power Protection (32) | √ | √ | √ | |
Out-of-stepProtection (78) | √ | √ | √ | |
Breaker failure protection (50BF) | √ | √ | √ | |
Mechanical Protection (MR) | √ | √ | √ | |
Data Collection | Current, Voltage | √ | √ | √ |
Active Power, Reactive Power | √ | √ | √ | |
Power Factor, Frequency | √ | √ | √ | |
Binary Inputs | 7 | 7 | 12 | |
Active-energy,Reactive-energy | √ | √ | √ | |
Fault Record | √ | √ | √ | |
Event Record | Protection Event | √ | √ | √ |
Alarm Event | √ | √ | √ | |
Remote Signaling Changing Event | √ | √ | √ | |
SOE Event | √ | √ | √ | |
Operation Record Event | √ | √ | √ | |
Statistics of Event Shift | √ | √ | √ | |
Control | Close or Open at Local or Remote Place | √ | √ | √ |
Remote Setting Value Modification | √ | √ | √ | |
Remote Protection On/ Off | √ | √ | √ | |
Protective Signal Output (Programmable) | 5 | 5 | 8 | |
Self-powered Module | √ | |||
DC24/48V Pulse Output or Current-typeTrip Output | √ | |||
Communication | RS485 | √ | √ | √ |
Ethernet Port | √ | |||
Debug Interface | √ | √ | √ |