Station unit Protocol Converter support Modbus RTU/TCP, IEC101, IEC 61850, IEC 60870-5-104, DNP 3.0 for Power Monitoring

Overview:

The ZNX6000 Station Manager is designed for the highest standards of performance, safety and reliability to meet requirements of a complex substation automation system (SAS). As a part of the SAS, it works as a station communication manager, which collects, stores and maps signals of relays, measurement units, control units and other IEDs in the substation to higher- level systems such as control center (CC) and distributed control system (DCS).
The ZNX6000 supports several protocols, such as IEC 60870-5-101/104, IEC 60870-5-103 and CDT. These protocols form a standard protocol package to satisfy most requirements. Data can be transmitted to and received from analog channel, digital channel or network connected to CC, DCS or other system. The direct transmission mode and the device independent avoid any interaction or influence with the the substation SCADA (Supervisory Control And Data Acquisition) system.

           

           

Funcations:
* Relay information acquisition
Through serial or Ethernet port, this device can communicate with protection relays to gather their information such as SOE records, tripping signals, supervision alarms, etc.
* Measurement & control IED information acquisition
Through serial or Ethernet port, this device can communicate with measurement & control IEDs and intelligent meters to gather their information such as sampled values, binary status, energy metering signals, etc.
* Auxiliary IED information acquisition
In addition, this device can gather information of other auxiliary devices, such as energy meter, which are useful or crucial for the operation and safety of substation.
* Remote control center communication
This device can realize the communication with multiple remote control centers with different protocols. The mapping transmission tables for different centers can be customized independently.
* Command record and query
This device records all the commands and operations, which include control selection, control execution, regulation, setting modification selection, setting modification execution, signal reset, etc. All these records can be viewed and queried with filter.
* History event record
This device automatically records the events during its service, which include self running state change, alarm from connected IED, communication failure alarm, etc.
* Time synchronization
This device supports several time synchronization formats, including IRIG-B, network SNTP, time message, etc. It can also
synchronize the connected IED with time message to unify the time in one substation.


Specification

           

Name

Description

CPU

Windows CE/32 Bit 400MHz RISC ARM926EJ

EMC Perormance 

Level 4

Product Size

482*230*44mm

Powered supply

110V, 220V AC/DC

Power consumption

10w

Communication ports

two 10/100M Ethernets(RJ45); ten RS485 Serial Ports

Operating conditons

Temperature -40°C to 85°C; Humidity 20% to 90%

           

Schematic diagram

           

           

                            ZNX3000                                                                                        ZNX3000 in site

                           

  Tel

  18694970015

  Email

  18694970015@163.com

     WeChat 

   

WeChat QR code
Nanjing Zhuneng Electric Co., Ltd

Mobile number: 18694970015

WeChat: power1411913

Email: 18694970015@163.com

Address: Building 16, Liandong U Valley Industrial Park, No.24 XuefuRoad, Jiangbei New District, Nanjing, Jiangsu, China

Copyright © 2024 Guodian Nanjing Automation Co., Ltd. All rights reserved.
Contact
Navigation
WhatsApp
Cloud computing support Feedback Manage